a) Abrasion/Wear Resistance loss in thickness(mm)
|
1.40 mm to 1.8 mm much below the required rate
of 3.5mm for non heavy duty and 2 mm for heavy duty flooring
|
b) Water Absorption (%) |
3% to 6% much below maximum of 10% allowed in IS 1237 |
|
c) Cold crushing strength/Compressive Strength requirement of minimum of 350 kgs/sq.cm.
|
400 kgs per cm sq to 600 kgs per cm. Sq.against the IS |
| d) Flexural strength/transverse Strength as per IS Specification |
For heavy duty flooring 40 to 60 kgs/sq.cm against 30 kgs/sq.cm |